Concrete wall sealer, wet look VB-2 CTS Chemistry

A water-based siloxane and silane sealer for walls and architectural concrete that deepens the colour of the material. It strongly lowers water uptake and leaves the pores open.

Surface

Concrete and floors

The surface the manufacturer intends this preparation for.

Concrete and floors

VB-2 is the concrete-wall version with a wet-look finish. It lowers water uptake more strongly than VB-1 and permanently deepens the colour of the concrete.

On a wall that has a consequence worth remembering: the effect covers the whole sealed area, and the boundary between a sealed section and a raw one will show. A wall is sealed in one go, not in sections with gaps between them.

A multi-component siloxane and silane product, water-based, alkali and UV resistant, meeting the requirements of PN-EN 1504-2 tab. 3.

Concrete accepts a sealer only when it is dry, clean and seasoned. A fresh slab is still giving off mix water and will push any coating off with it.

  1. Remove cement laitance and mortar residue - left under the sealer, they come away with it.
  2. Degrease the surface. Oil stains need an alkaline cleaner, not a detergent.
  3. Primed or painted floors need the old coating removed; a penetrating sealer will not bond through paint.
  4. Check the moisture in the substrate. Some solvent-based products require below 5-6 % - the figure is in the technical data.
  5. Ventilate the room if you are working with a solvent-based product indoors.

A new floor and fresh precast units have to season. Manufacturers give that period on the data sheet; for precast concrete it is usually around 28 days.

Before sealing the whole area, test on a patch hidden by a planter or in a corner of the patio. The same product can read differently on two batches of the same material, and on a surface with old coating left on it, it will not bond at all.

Coats
1
Base
water-based
Finish
wet look
Application method
soft roller, brush, spray
Dilution
Ready to use - do not dilute
Where to use
indoors, outdoors
Product density
approx. 1.1 kg/dm³
pH
approx. 7
Colour
milky white; dries colourless and gives a wet-look finish
Rain resistance
after 5-6 hours
Water absorption coefficient
Wd < 0.1 kg/m²·h^0.5 or < 7.5 % per PN-EN 1504-2 / EN 13580
Alkali resistance
< 10 % per PN-EN 1504-2 / EN 13580
Penetration depth
> 5 mm, per EN 14630
Standard
PN-EN 1504-2 table 3
Will a sealer stop my floor dusting?

Products that form a polymer layer bind the loose particles on the surface, and manufacturers describe them as dust-free. That is not a substitute for a hardener where the concrete itself is dusting because it was poorly floated - the problem is then in the slab, not on it.

Can I seal concrete indoors?

Yes, if the technical data lists indoor use. With solvent-based products you have to ventilate during application and for the period the manufacturer states.

What do I do about old oil stains?

Remove them before sealing, with an oil stain remover. A sealer applied over a stain seals it in and fixes it - oil will not evaporate through a sealed layer.

Does a sealer protect against road salt?

It limits the ingress of water and the salts dissolved in it. How far that goes depends on the product, and we quote it from the manufacturer's data sheet rather than generalising.

What exactly separates the -1 from the -2?

Composition and finish. The -1 versions are single-component, based on siloxanes alone, and dry colourless. The -2 versions are multi-component - siloxanes with modified silanes - and give a lasting wet-look finish. Both meet PN-EN 1504-2 tab. 3 and both leave the pores open.

How much product do I need?

The manufacturer of this range publishes no coverage in square metres per litre, because the product is applied to saturation and the absorbency of the material decides consumption entirely. The practical method: seal one square metre, measure what it took, and multiply by your area with some margin.

When is the surface rain resistant?

The manufacturer states 5-6 hours. During that time the freshly sealed surface also has to be kept out of direct sun.

The technical sheet and safety data sheet will be available after approval.

Coverage calculator

This product has no stated coverage yet, so we cannot work out the requirement.

The manufacturer publishes no coverage figure for this range. The sealer is applied to saturation in one heavier coat, repeated wet-on-wet on absorbent material.

The calculator starts once the manufacturer states the coverage.

Related products

Looking for another surface?

Go directly to the right category. We do not imply compatibility across materials.