Water-based sealer for concrete and precast units EH-17 EKSIL

A water-based silane sealer for concrete and precast concrete products. Once dry the film is invisible and changes neither the appearance nor the colour of the material. Dries in 1-2 hours at 20 °C.

Surface

Block paving

The surface the manufacturer intends this preparation for.

Block paving

EH-17 is a water-based silane sealer aimed at concrete and precast concrete products - edgings, palisades, garden elements, blocks.

What sets it apart is the pace of work: drying in 1-2 hours at 20 °C and protection from rain for a minimum of two hours. With a short weather window that is a real advantage over products needing a full day.

The manufacturer states consumption by volume rather than in square metres per litre: 0.20-0.35 l/m² on concrete and 0.20-0.25 l/m² on precast units. The film is invisible and changes neither the appearance nor the colour of the material.

The usual reason a sealing job fails is not the product but the substrate. A sealer will not bond to a surface with grease, lime efflorescence or an old coating on it.

  1. Wash the paving. Lift oil stains with a degreasing cleaner - water alone, even under pressure, will not shift them.
  2. Remove lime efflorescence with a product made for it, not with hydrochloric acid from the builders' merchant.
  3. Make good the joints and let them set. Sealer applied over an empty joint runs straight into the sub-base.
  4. Wait until the paving is dry all the way through, not just on top. Moisture trapped under the film can bloom it white.
  5. Check the forecast. Rain within a day of application will wash off a fresh coat.

New paving has to season first. Manufacturers state that period on the data sheet - usually around 28 days from the date the block was made. The figure for each product is under "Technical data".

Before sealing the whole area, test on a patch hidden by a planter or in a corner of the patio. The same product can read differently on two batches of the same material, and on a surface with old coating left on it, it will not bond at all.

Coats
1
Base
water-based
Finish
invisible
Application method
roller, brush, low-pressure spray
Dilution
Do not dilute
Application temperature
+5 to +35 °C
Drying time
2 h
Where to use
indoors, outdoors
Chemical base
water-based silane sealer
Appearance
milky liquid; the dried film is invisible
Density
1.00-1.04 kg/l
pH
13-14
Consumption - concrete
0.20-0.35 l/m²
Consumption - precast concrete
0.20-0.25 l/m²
Substrate temperature
5-25 °C
Protect from rain
minimum 2 h after application
Will the sealer change the colour of my paving?

That depends on the finish given in the technical data. An invisible product leaves the colour alone, a wet-look version deepens it permanently, and a colour sealer gives it a new shade. Each product's finish is listed under "Technical data".

How do I know when to seal again?

By how the water behaves. While it still beads on the surface, the treatment is working. Once water starts soaking in and dark patches return after rain, the protection has worn out. We do not quote a number of years, because it depends on traffic, sun and whether the drive is salted in winter.

Can I apply sealer to wet paving?

No. Water occupies the pores the product is meant to enter, and stays trapped under the film. The result is often a milky bloom that cannot be removed without stripping the coat. The exceptions - products that allow slight surface dampness - say so in their technical data.

How much do I need to buy?

Use the calculator under the product description: it takes the manufacturer's coverage figure, the number of coats and the absorbency of the substrate, and turns them into pack sizes. On older, thirstier paving, work to the lower end of the coverage range.

Will sealing make the paving slippery?

Penetrating products form no film on the surface and do not change its grip. Where a manufacturer says something about slipperiness, we quote it in the technical data. If the surface is already slippery, the right product is an anti-slip treatment, not a sealer.

How do I turn 0.25 l/m² into packs?

Multiply the area by the consumption: 40 m² × 0.25 l/m² is 10 litres. Note that this is the inverse of "square metres per litre" - the higher the number, the more product you use.

Are two hours to rain enough?

That is the minimum the manufacturer gives at 20 °C. At lower temperatures and higher humidity drying takes longer - it is better to have margin in the forecast.

The technical sheet and safety data sheet will be available after approval.

Coverage calculator

This product has no stated coverage yet, so we cannot work out the requirement.

The manufacturer states consumption by volume: concrete 0.20-0.35 l/m², precast concrete 0.20-0.25 l/m².

The calculator starts once the manufacturer states the coverage.

Related products

Looking for another surface?

Go directly to the right category. We do not imply compatibility across materials.